The tent packaged unit was developed primarily to provide air cooling in tents or transportable buildings. It not only provides greater comfort but also protects equipment and materials from hot weather damage.
The tent packaged unit is fitted with flexible duct and the unit itself must be located outside. The function of the tent packaged unit is based on a cooling circuit and powerful fans. The evaporator section contains the evaporator and a centrifugal fan, which draws warm internal air of the tent through the cold evaporator and blows out the cooled air through the side or the top of the unit. The condenser section contains two condenser coils and a large axial fan, returning the heat taken from the internal air to the outside atmosphere.
The tent packaged unit also have heat pump, can supply warm air into the tent in winter. Use the Panasonic scroll compressor, Amrta tent packaged unit can supply hot air at -10oC to 20oC.
● Self-contained package design
Easy installation with just connecting condensate drainage and electrical power supply, equipped with connecting plug.
● Special unit structure design
The tent wall can be installed in between of evaporator and condenser with the gap of 100-150mm.
● Plenum chamber
3 meter height with better air circulation and strong air flow.
● Digital controller
LED display, timer display, fan speed display, temperature display, error code display, mode display.
● Long distance air supply
High external static pressure (max 350pa) with 30 meter air throws.
● Easy maintenance
Air filter is easily dismantled and cleaned.
Structure
Model | TA-14 | TA-28 | TA-42 | TA-56 | TA-84 | TA-100 | ||
Power supply | V~/PH/HZ | 380/3/50 | ||||||
Cooling | Capacity | kW | 14.0 | 28.0 | 42.0 | 56.0 | 84.0 | 100.0 |
HP | 5 | 10 | 15 | 20 | 30 | 36 | ||
Btu/h | 48000 | 96000 | 144000 | 192000 | 290000 | 340000 | ||
Power input | kW | 4.90 | 9.80 | 14.80 | 19.80 | 29.80 | 35.60 | |
Running current | A | 8.7 | 17.5 | 26.1 | 34.9 | 51 | 71.7 | |
Start current | A | 26.0 | 35.0 | 52 | 70 | 95 | 95 | |
EER | W/W | 2.86 | 2.86 | 2.84 | 2.83 | 2.82 | 2.81 | |
E.S.P | Pa | 150 | 150 | 250 | 250 | 350 | 350 | |
Evaporator | Fin material type | Hydrophilic louvered aluminum fin | ||||||
Tube material type | Innergroover tube type | |||||||
Number of row | 3 | 4 | 4 | 4 | 5 | 5 | ||
Evaporator fan | Type | High efficiency Centrifugal | ||||||
Air discharge type | Top discharge | |||||||
Rated ESP air flow | m³/h | 2500/1800 | 5000/3200 | 8000/5500 | 10000/7000 | 12000 | 15000 | |
Condenser | Fin material type | Hydrophilic louvered aluminum fin | ||||||
Tube material type | Innergroover tube type | |||||||
Number of row | 2 | 4 | 3 | 3 | 4 | 4 | ||
Condensing fan | Type | High efficiency axial | ||||||
Air discharge type | Top discharge | |||||||
Rated air flow | m³/h | 5000 | 11000 | 16000 | 22000 | 32000 | 35000 | |
Numbers | Pcs | 1 | 1 | 2 | 2 | 2 | 2 | |
Refrigerant | Type | R410A | ||||||
Unit dimension | Width | mm | 1060 | 1060 | 1060 | 2200 | 2200 | 2200 |
Depth | mm | 1270 | 1700 | 1940 | 2360 | 2900 | 3600 | |
Height | mm | 2210 | 2210 | 2660 | 2660 | 2660 | 2660 | |
Unit noise level | dB(A) | 65 | 67 | 70 | 75 | 71 | 71 | |
Unit weight | kg | 320 | 450 | 560 | 650 | 1680 | 1840 |
Notes:
Nominal cooling capacities are based on the following conditions:Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB;
Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.