Jinan Amrta Air Conditioning Co.,Ltd
Home Product Ground Source Heat Pump Unit

Ground Source Heat Pump Unit

Available in: Cooling, Heating, Heat Recovery

Capacity: 130kW~2500kW

Refrigerant: R410A/R134A/R407C/R22

Application: Industry Process Cooling, Commercial, Workshop, Warehouse, Office Building, Pharmaceutical

● 29 sizes available ranging from 127 kW to 2450 kW heating capacity.

 

● Reusable: using solar energy stored in earth as cooling & heating source.

 

● Great environmental and economic benefit: no boiler or cooling tower; less space, less CO2 and less initial investment.

 

● Acting as multi-function unit such as cooling, heating, sanitary hot water separately or simultaneously.

 

● Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.

 

● Semi-hermetic screw compressor for mod.130 to 2500. Each compressor is equipped with a crankcase heater and a thermal overload cut-out; the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.

 

● The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.

 

● Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.
Shell and tube type evaporator, factory insulated with flexible close cell material.

 

● The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.

 

● LCD display, touch screen control panel as standard.
Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

 

● For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.

Model

Unit

130

170

200

240

260

280

310

360

380

420

Cooling capacity*

kW

130

170

200

240

260

280

310

360

380

420

Heating capacity*

kW

127

167

196

235

255

274

304

353

372

412

Power supply

380-415V/3Ph/50Hz

Compressor

Qty/refrigerant circuit

Nr.

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

Cooling power input*

kW

24

31

37

44

48

52

57

67

70

78

Heating power input*

kW

43

56

66

80

86

93

103

120

126

140

Energy adjustment steps

step

25% – 100%

Max. current for wiring

A

87

108

128

165

165

165

165

185

185

258

Refrigerant charge

kg

23

30

36

43

46

50

55

64

68

75

Evaporator

Water side pressure drop

kPa

42

45

45

45

45

46

46

46

47

46

Pipe size

mm

DN65

DN80

DN100

DN100

DN100

DN100

DN100

DN125

DN125

DN125

Water flow rate in cooling*

m3/h

22

29

34

41

45

48

53

62

65

72

Water flow rate in heating*

m3/h

9

12

14

17

18

19

22

25

26

29

Condenser

Water side pressure drop

kPa

42

45

44

44

45

45

44

44

44

42

Pipe size

mm

DN80

DN80

DN100

DN100

DN100

DN100

DN100

DN125

DN125

DN125

Water flow rate in cooling*

m3/h

12

16

19

22

24

26

29

33

35

39

Water flow rate in heating*

m3/h

22

29

34

40

44

47

52

61

64

71

Dimensions

Length

mm

2635

2760

2740

2880

2870

2870

2970

3170

3280

3280

Width

mm

1090

1115

1175

1125

1125

1125

1230

1200

1285

1285

Height

mm

1625

1555

1650

1645

1685

1685

1685

1685

1805

1805

Net weight

kg

1600

1800

1900

2000

2100

2200

2250

2400

3000

3100

Noise level**

dB(A)

68

69

69

70

70

72

73

73

73

73

 

Model

Unit

480

530

610

680

710

760

860

960

1000

1120

Cooling capacity*

kW

480

530

610

680

710

760

860

960

1000

1120

Heating capacity*

kW

470

519

598

666

696

745

843

941

980

1098

Power supply

380-415V/3Ph/50Hz

Compressor

Qty/refrigerant circuit

Nr.

1/1

1/1

1/1

1/1

2/2

2/2

2/2

2/2

2/2

2/2

Cooling power input*

kW

89

98

113

126

131

141

159

178

185

207

Heating power input*

kW

159

176

203

226

236

252

286

319

332

372

Energy adjustment steps

step

25% – 100%

12.5% – 100%

Max. current for wiring

A

302

302

357

378

2×185

2×185

2×258

2×258

2×302

2×302

Refrigerant charge

kg

85

94

108

121

126

135

153

171

178

199

Evaporator

Water side pressure drop

kPa

46

46

46

47

47

46

47

46

46

46

Pipe size

mm

DN125

DN125

DN125

DN150

DN150

DN150

DN150

DN200

DN200

DN200

Water flow rate in cooling*

m3/h

83

91

105

117

122

131

148

165

172

193

Water flow rate in heating*

m3/h

33

37

42

47

49

53

60

67

70

78

Condenser

Water side pressure drop

kPa

42

42

44

42

44

42

44

42

44

44

Pipe size

mm

DN125

DN125

DN125

DN150

DN125

DN125

DN125

DN125

DN125

DN150

Water flow rate in cooling*

m3/h

44

49

57

63

66

70

80

89

93

104

Water flow rate in heating*

m3/h

81

89

103

115

120

128

145

162

169

189

Dimensions

Length

mm

3505

3505

3505

3520

4005

4505

4505

4505

4560

4560

Width

mm

1280

1315

1375

1380

1415

1415

1415

1415

1460

1460

Height

mm

1970

1990

1980

1980

1975

2000

2000

2000

2090

2090

Net weight

kg

3500

3800

4000

4100

4210

4400

4740

5600

6600

6800

Noise level**

dB(A)

74

74

74

73

74

74

74

74

74

74

 

Model

Unit

1200

1250

1360

1470

1720

1840

2000

2350

2500

Cooling capacity*

kW

1200

1250

1360

1470

1720

1840

2000

2350

2500

Heating capacity*

kW

1176

1225

1333

1441

1686

1803

1960

2303

2450

Power supply

380-415V/3Ph/50Hz

Compressor

Qty/refrigerant circuit

Nr.

2/2

2/2

2/2

4/4

4/4

4/4

4/4

4/4

4/4

Cooling power input*

kW

222

231

252

272

319

341

370

435

463

Heating power input*

kW

399

415

452

488

571

611

664

781

831

Energy adjustment steps

step

12.5% – 100%

6.25% – 100%

Max. current for wiring

A

2×357

2×357

2×378

4×185

4×258

4×258

4×302

4×357

4×357

Refrigerant charge

kg

213

222

242

261

306

327

356

418

444

Evaporator

 

Water side pressure drop

kPa

46

46

46

45

45

46

46

47

47

Pipe size

mm

DN200

DN200

DN200

2×DN150

2×DN150

2×DN200

2×DN200

2×DN200

2×DN200

Water flow rate in cooling*

m3/h

206

215

234

253

296

316

344

404

430

Water flow rate in heating*

m3/h

84

87

95

102

120

128

139

164

174

Condenser

 

Water side pressure drop

kPa

44

42

45

52

52

52

52

52

52

Pipe size

mm

DN150

DN150

DN150

2×DN200

2×DN200

2×DN200

2×DN200

2×DN200

2×DN200

Water flow rate in cooling*

m3/h

111

116

126

136

159

170

185

218

232

Water flow rate in heating*

m3/h

202

211

229

248

290

310

337

396

421

Dimensions

 

Length

mm

4660

4660

4660

4600

4650

4690

4730

4780

4800

Width

mm

1585

1585

1585

2250

2270

2300

2340

2380

2400

Height

mm

2215

2215

2240

2350

2380

2410

2450

2470

2500

Net weight

kg

7000

7400

8000

8800

9000

9800

11600

12300

13000

Noise level**

dB(A)

74

74

76

80

80

81

81

82

82

* Performance values refer to the following conditions:
Cooling: condenser water inlet/outlet temperature: 18ºC/29ºC, evaporator water inlet/outlet temperature: 12ºC/7ºC.
Heating: condenser water inlet/outlet temperature: 40ºC/45ºC, evaporator water inlet/outlet temperature: 15ºC/7ºC.
** Noise level measured in free field condition at distance of 1 meter.

Related Solutions & Applications