Wide Operation Range
The unit could operate perfectly between 52°C in hot summer and -15°C in cold winter making you feel like spring all year around with advanced system design and
strict matching test(cooling in -15°C ).
DC Inverter Compressor
Made of rare earth permanent magnetic material, the rotor could change the motor’s round speed by changing the DC voltage motor, thus overcome the electromagnetic noise and rotor loss of AC inverter compressor, then achieves high efficiency as well as low noise.
Auto Restart Function
The AC can automatically memorize the operation setting when power is cut off accidently. It can return to previous setting when power resumes.
Recover the former operation state when power is restored, no need restart the unit manually.
Fast Cooling / Heating Technology
The DC Inverter Compressor system reaches full load rapidly providing less temperature fluctuation and an improved living environment, bringing great user experience.
Accurate Temperature Control
According to change trend of indoor ambient temperature, the unit can use PI algorithm to calculate capacity demand percentage of indoor unit, control operating
frequency of compressor in real time and reach accurate control of room temperature.
Flexible and Diversified Matching Of Indoor and Outdoor Unit
Amrta offers a variety indoor units, more than 100 models of 7 types. Capacity ranges are from 2.2kW to 14kW. It is full compliance with residential and light commercial place. Our systems can operate up to 130% of capacity which allows any system to be designed to the customers and applications needs.
Wide Voltage Design
In country with unstable voltage, ARV can also run stably.
Long Piping Length
Max. Total piping length — 100/150m
Max. Actual piping length — 60/100m
Max. Level diff erence between indoor units — 10/15m
Max. Level diff erence between ODU and IDU units — 40/50m
Max. piping length from 1st indoor branch to the farthest indoor unit — 20m/40m
All DC Inverter
50Hz/60Hz
Model | Outdoor | ARV-H080/NR1 | ARV-H100/NR1 | ARV-H120/NR1 | ARV-H140/NR1 | ARV-H160/NR1 | |
Capacity | Cooling | kW | 8.00 | 10.00 | 12.30 | 14.00 | 16.00 |
Heating | kW | 9.00 | 11.50 | 13.20 | 16.50 | 18.00 | |
Electrical Data |
Power Supply | V~,Hz,Ph | 220~240,50/60,1 | ||||
Cooling Power Input | kW | 2.30 | 3.00 | 3.25 | 3.95 | 4.80 | |
Heating Power Input | kW | 2.40 | 3.20 | 3.41 | 4.05 | 4.80 | |
Cooling Current | A | 10.10 | 13.20 | 14.30 | 17.30 | 21.10 | |
Heating Current | A | 10.50 | 14.00 | 15.00 | 17.80 | 21.10 | |
EER | 3.48 | 3.33 | 3.78 | 3.54 | 3.33 | ||
COP | 3.75 | 3.59 | 3.87 | 4.07 | 3.75 | ||
SEER | 6.20 | 6.10 | 6.10 | 6.10 | 6.10 | ||
SCOP | 4.20 | 4.10 | 4.10 | 4.00 | 4.00 | ||
Performance | Air Flow Volume | m³/h | 4154 | 4154 | 7200 | 7200 | 7200 |
Noise Level | DB(A) | 56 | 56 | 57 | 57 | 57 | |
Piping Limit | Level Difference Between IDU and ODU | m | 50 | 50 | 50 | 50 | 50 |
Level Difference Between IDU and IDU | m | 10 | 10 | 15 | 15 | 15 | |
Between the First Brance and the Farthest IDU | m | 40 | 40 | 40 | 40 | 40 | |
Total Pipe Length | m | 100 | 100 | 150 | 150 | 150 | |
Max. No. of Indoor Units | unit | 4 | 5 | 7 | 8 | 9 | |
Connection Ratio | % | 50~130 | 50~130 | 50~130 | 50~130 | 50~130 | |
Dimension (WxDxH) | Net | mm | 970x395x805 | 970x395x805 | 940x370x1325 | 940x370x1325 | 940x370x1325 |
Packing | mm | 1105x495x895 | 1105x495x895 | 1080x430x1440 | 1080x430x1440 | 1080x430x1440 | |
Weight | Net | kg | 66 | 66 | 86 | 86 | 93 |
Gross | kg | 71 | 71 | 91 | 91 | 98 | |
Refrigerant Type | R410a | R410a | R410a | R410a | R410a | ||
Pipe Diameter |
Liquid Side | mm(inch) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) |
Gas Side | mm(inch) | 15.88(5/8) | 15.88(5/8) | 15.88(5/8) | 15.88(5/8) | 19.05(3/4) | |
Operation Range |
Cooling | ℃ | -15~52 | -15~52 | -15~52 | -15~52 | -15~52 |
Heating | ℃ | -15~27 | -15~27 | -15~27 | -15~27 | -15~27 | |
Stuffing Quantity |
20/40/40H | unit | 44/96/144 | 44/96/144 | 26/54/54 | 26/54/54 | 26/54/54 |
ARV Mini Series
Model | Outdoor | ARV-H220/5R1A | ARV-H280/5R1A | |
Capacity |
Cooling | kW |
22.40 |
26.00 |
Heating | kW |
24.50 |
28.50 |
|
Electric Data | Power Supply | V~,Hz,Ph | 380~415,50,3 | |
Cooling Power Input | kW | 7.20 | 8.40 | |
Heating Power Input | kW | 6.70 | 7.90 | |
Cooling Current | A | 11.60 | 13.50 | |
Heating Current | A | 11.00 | 13.00 | |
EER | 3.11 | 3.10 | ||
COP | 3.66 | 3.61 | ||
Performance |
Air Flow Volume | m3/h |
9000 |
9000 |
Noise Level | dB(A) |
60 |
60 |
|
Piping Limit | Vertical Pipe Length | m | ≤30 | ≤30 |
Actual Pipe Length | m | 45 | 45 | |
Equivalent Pipe Length | m | 50
|
50
|
|
Total Pipe length | m |
100 |
100 |
|
Max. No. of Indoor Units | unit | 11 | 12 | |
Connection Ratio | % | 50~130 | 50~130 | |
Dimension (WxDxH) |
Net | mm | 1120×400×1510 | 1120×400×1510 |
Packing | mm | 1270×560×1710 | 1270×560×1710 | |
Weight |
Net | kg |
150 |
150 |
Gross | kg |
170 |
170 |
|
Refrigerant Type | R410a | R410a | ||
Pipe Diameter |
Liquid Side | mm(inch) |
9.52(3/8) |
9.52(3/8) |
Gas Side | mm(inch) |
22.22(7/8) |
22.22(7/8) |
|
Operation Range |
Cooling |
°C |
-10~52 |
-10~52 |
Heating |
°C |
-15~24 |
-15~24 |
|
Stuffing Quantity | 20/40/40H | unit | 17/37/37 | 17/37/37 |
Notes:
1.Cooling Capacity: Indoor temperature 27°C DB/ 19°C WB; Outdoor temperature:35°C DB/ 24°C WB.
2.Cooling Capacity (Tropical): Indoor temperature 27°C DB/19°C WB;Outdoor temperature:46.1°C DB.
3.Heating Capacity: Indoor temperature 20°C DB; Outdoor temperature: 7°C DB/ 6°C WB.
4.Piping Length: Equivalent piping length: 7.5m, level difference: 0m.
5.Anechoic chamber conversion value, measured in test room. During actual operation. These values are normally somewhat higher as a result of ambient conditions.
6.The above designs and specifications are subject to change without prior notice. Final specifications please refer to technical specification provided by sales representative.