Jinan Amrta Air Conditioning Co.,Ltd
Home Product Air-Cooled Modular Chiller

Air-Cooled Modular Chiller

Available in: Cooling, Heating, Heat Recovery, Free-Cooling

Capacity: 65kW~520kW

Refrigerant: R410A/R134A/R32/R290

Application: Commercial Building, School, Hotel, Hospital, Workshop, Shopping Mall, Church, Data Center

Characteristics

The master module can work independently or together with up to 16 slave modules.
Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
3-phase scroll type compressor, with builtin thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.

Evaporator built with high efficiency shell and tube type heat exchanger, factory insulated with flexible close cell material.
Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.
Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve, high & low pressure switch. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.
Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.

 

Electric panel
Electric panel consist of:

compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit)
Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

 

Optional

Paddle flow switch;
Metallic filter for hydraulic circuit;
Water pump;
Rubber antivibration mounting;
Heat recovery functions;

Free-cooling

Model Unit AW65 AW65 AW130 AW190 AW260

Cooling capacity

kW 65 65 130 190 260

Heating capacity

kW 69 69 138 207 276
Power input

 

Cooling kW 20.5 21 42.4 63.4 84.8
Cooling rated current A 36.5 36.5 73 110 146
Heating kW 21.5 21.5 43.4 64.9 86.8
Heating rated current A 36.2 37.2 75.2 112.2 150.1
EER kW/kW 3.17 3.09 3.07 3.08 3.07
COP kW/kW 3.21 3.21 3.18 3.19 3.18
Power supply V/Ph/Hz 380~415/3/50
Compressor Type   Scroll(Fixed speed)
Quantity Pieces 2 1 2 3 4
Refrigerant Type   R410A
Refrigerant control   EEV/TEV
Weight kg 15 15 15×2 15×3 15×4
Air side heat exchanger Type   Fin-coil
Quantity of fan motor  Pieces 2 2 2 4 4
Air flow m³/h 25000 25000 50000 75000 100000
Water side heat exchanger Type   Shell and tube
Water pressure drop kPa 42 42 41 44 44
Water connection size  mm DN65 DN65 DN65 DN80 DN80
Water flow  m³/h 11.2 11.2 22.4 33.6 44.8
Water pipe connection type   Flange
External dimension L mm 2120 2120 2260 2260 2260
W mm 1100 1100 1250 2410 2410
H mm 2020 2020 2380 2500 2500
Weight Net weight kg 650 650 1270 1900 2540
Operation weight kg 680 680 1350 2030 2700
Noise level dB(A) 68 68 69 70 70
Operation water temp. °C Cooling: 0~17(Less than 5°C must add antifreeze) Heating: 25~51
Ambient temp. °C Cooling: -10~46, Heating: -15~24

 

Model Unit AW325 AW390 AW455 AW520

Cooling capacity

kW 325 390 455 520

Heating capacity

kW 345 414 483 552
Power input

 

Cooling kW 105 126 147 168
Cooling rated current A 182.5 219 255.5 292
Heating kW 107.5 129 150.5 172
Heating rated current A 186 223.2 260.4 297.6
EER kW/kW 3.07 3.07 3.07 3.07
COP kW/kW 3.18 3.18 3.18 3.18
Power supply V/Ph/Hz 380~415/3/50
Compressor Type   Scroll(Fixed speed)
Quantity Pieces 5 6 7 8
Refrigerant Type   R410A
Refrigerant control   EEV/TEV
Weight kg 15×5 15×6 15×7 15×8
Air side heat exchanger Type   Fin-coil
Quantity of fan motor  Pieces 6 6 8 8
Air flow m³/h 125000 125000 125000 125000
Water side heat exchanger Type   Shell and tube
Water pressure drop kPa 47 50 48 50
Water connection size  mm DN125 DN150 DN150 DN150
Water flow  m³/h 56 67.2 78.4 89.6
Water pipe connection type   Flange
External dimension L mm 3596 3596 4793 4793
W mm 2268 2268 2268 2268
H mm 2510 2510 2510 2510
Weight Net weight kg 3160 3680 4380 4900
Operation weight kg 3300 3860 4510 5050
Noise level dB(A) 74 76 77 77
Operation water temp. °C Cooling: 0~17(Less than 5°C must add antifreeze) Heating: 25~51
Ambient temp. °C Cooling: -10~46, Heating: -15~24

Specifications are based on the following conditions:
*Cooling: chilled water inlet/outlet: 12°C / 7°C, and outdoor ambient temp. of 35°C DB.
**Heating: warm water inlet/outlet: 40°C / 45°C, and outdoor ambient temp. 7°CDB/6°CWB.
***Water side fouling factor: 0.086m2.°C/kW.
****1m away in open field(sound pressure).

 

 

Related Solutions & Applications